APT 3700N

[vc_row rt_row_background_width=”fullwidth” rt_row_content_width=”default” rt_row_style=”default-style” rt_row_height=”” rt_column_gaps=”” rt_row_shadows=”” rt_row_borders=”” rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”cover” rt_bg_position=”right top” rt_bg_attachment=”scroll” rt_bg_layer=”” rt_bg_video_format=”self-hosted” rt_class=”rt-1561408″ rt_paddings=”10px,10px,,” rt_margins=”,,,” rt_content_margins=”,,,” rt_tablet_paddings=”,,,” rt_tablet_margins=”,,,” rt_tablet_content_margins=”,,,” rt_sp_paddings=”,,,” rt_sp_margins=”,,,” rt_sp_content_margins=”,,,”][vc_column rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”auto auto” rt_bg_position=”right top” rt_bg_attachment=”scroll”][vc_custom_heading text=”APT 3700N Smart Pressure Transmitter” font_container=”tag:h1|font_size:28|text_align:left” use_theme_fonts=”yes” css=”.vc_custom_1545891533550{margin-top: 0px !important;margin-bottom: 0px !important;padding-top: 0px !important;padding-bottom: 0px !important;}”][/vc_column][/vc_row][vc_row rt_row_background_width=”fullwidth” rt_row_content_width=”default” rt_row_style=”default-style” rt_row_height=”” rt_column_gaps=”” rt_row_shadows=”” rt_row_borders=”” rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”cover” rt_bg_position=”right top” rt_bg_attachment=”scroll” rt_bg_layer=”” rt_bg_video_format=”self-hosted”][vc_column width=”1/3″ rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”auto auto” rt_bg_position=”right top” rt_bg_attachment=”scroll”][vc_single_image image=”1121″ img_size=”full” alignment=”center” style=”zoooom” onclick=”link_image”][/vc_column][vc_column width=”2/3″ rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”auto auto” rt_bg_position=”right top” rt_bg_attachment=”scroll”][vc_column_text css=”.vc_custom_1545891548133{margin-bottom: 0px !important;}”]The APT 3700N Smart Pressure Transmitter is a microprocessor-based high-performance transmitter, which has flexible pressure calibration and output, automatic compensation of ambient temperature and process variable, the configuration of various parameters, communication with HART protocol. The application is very various, as measuring pressure, flow, and level by the application method. All data of the sensor is to be input, modified and stored in EEPROM.[/vc_column_text][vc_custom_heading text=”Function” font_container=”tag:h2|font_size:20|text_align:left” use_theme_fonts=”yes” css=”.vc_custom_1541154244450{margin-top: 0px !important;margin-bottom: 0px !important;padding-top: 15px !important;padding-bottom: 10px !important;}”][vc_column_text]

  • Flexible Sensor Input: DP, GP, AP, Vacuum
  • Various Output : 4 ~20mA , Digital Signals
  • Setting Various Parameters: Zero/Span, Trim, Unit, Fail-mode, etc.
  • Self Diagnostic Function: Sensor, Memory A/D Converter, Power, etc.
  • Digital Communication with HART protocol
  • Explosion-proof Approval KOSHA
  • Qualified per IEEE Std 344-1987/2004 and IEEE Std 323-1983/2003, NRC Regulatory Guide 1.180 (Rev.1)

[/vc_column_text][/vc_column][/vc_row][vc_row rt_row_background_width=”fullwidth” rt_row_content_width=”default” rt_row_style=”default-style” rt_row_height=”” rt_column_gaps=”” rt_row_shadows=”” rt_row_borders=”” rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”cover” rt_bg_position=”right top” rt_bg_attachment=”scroll” rt_bg_layer=”” rt_bg_video_format=”self-hosted”][vc_column rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”auto auto” rt_bg_position=”right top” rt_bg_attachment=”scroll”][vc_tta_tabs][vc_tta_section i_icon_fontawesome=”fa fa-pencil-square-o” add_icon=”true” title=”Features” tab_id=”1541150791848-f5e45dd6-376395e2-9936″][vc_row_inner rt_row_background_width=”fullwidth” rt_row_content_width=”default” rt_row_style=”global-style” rt_row_height=”” rt_column_gaps=”” rt_row_borders=”” rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”cover” rt_bg_position=”right top” rt_bg_attachment=”scroll” rt_bg_layer=”” rt_bg_video_format=”self-hosted”][vc_column_inner width=”1/2″ rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”auto auto” rt_bg_position=”right top” rt_bg_attachment=”scroll”][vc_column_text]

  • High Reference Accuracy: ±0.075% of Calibrated Span
  • Long-Term Stability: ± 0.25% URL per 24 months
  • High Rangeability (100: 1)
  • Data Configuration with HART Configurator
  • Zero Point Adjustment

[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/2″ rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”auto auto” rt_bg_position=”right top” rt_bg_attachment=”scroll”][vc_column_text]

  • Continuous Self-Diagnostic Function
  • Automatic Ambient Temperature Compensation
  • Fail-mode Process Function
  • EEPROM Write Protection
  • Equipment Qualifications
  • Environmental Qualification
  • Seismic Qualification and EMI / RFI Test

[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_tta_section][vc_tta_section i_icon_fontawesome=”fa fa-book” add_icon=”true” title=”Specifications” tab_id=”1541150791868-27c83745-4a4c95e2-9936″][vc_column_text]

  • Model Name: APT3700N
  • Protocol: 4 to 20mA+Digital Communication, HART 5
  • Trim ability: Zero, DAC, FULL
  • Power supply & Load Requirement: 250 to 550 ohm @ 24 Vdc, Loop Powered
  • Failure Mode: Low ≤ 3.78 mA, High ≥ 21.1 mA
  • External Buttons: Zero & Span 2 buttons for device configuration
  • Process Temp. limit: -40 to 120℃ ( -104 to 248℉ )
  • Range Ability: 100:1
  • Stability: ±0.125% URL for 36 months

[/vc_column_text][/vc_tta_section][vc_tta_section i_icon_fontawesome=”fa fa-file-text” add_icon=”true” title=”Documents” tab_id=”1541151331745-25407355-c00695e2-9936″][vc_column_text]  Catalog

 Manual[/vc_column_text][/vc_tta_section][vc_tta_section i_icon_fontawesome=”fa fa-wpforms” add_icon=”true” title=”Certificates” tab_id=”1542625142301-22dfa560-59aa”][vc_row_inner rt_row_background_width=”fullwidth” rt_row_content_width=”default” rt_row_style=”global-style” rt_row_height=”” rt_column_gaps=”” rt_row_borders=”” rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”cover” rt_bg_position=”right top” rt_bg_attachment=”scroll” rt_bg_layer=”” rt_bg_video_format=”self-hosted”][vc_column_inner rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”auto auto” rt_bg_position=”right top” rt_bg_attachment=”scroll”][vc_column_text]  NEP

 KCs Ex d[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_tta_section][vc_tta_section i_icon_fontawesome=”fa fa-files-o” add_icon=”true” title=”Drawings” tab_id=”1542625184657-c88e5bfd-5e5b”][vc_row_inner rt_row_background_width=”fullwidth” rt_row_content_width=”default” rt_row_style=”global-style” rt_row_height=”” rt_column_gaps=”” rt_row_borders=”” rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”cover” rt_bg_position=”right top” rt_bg_attachment=”scroll” rt_bg_layer=”” rt_bg_video_format=”self-hosted”][vc_column_inner width=”1/2″ rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”auto auto” rt_bg_position=”right top” rt_bg_attachment=”scroll”][vc_column_text]  3700N-D OUTLINE

 3700N-D-MP OUTLINE[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/2″ rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”auto auto” rt_bg_position=”right top” rt_bg_attachment=”scroll”][vc_column_text]  3700N-G OUTLINE[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_tta_section][/vc_tta_tabs][/vc_column][/vc_row]