APT 3500

[vc_row rt_row_background_width=”fullwidth” rt_row_content_width=”default” rt_row_style=”default-style” rt_row_height=”” rt_column_gaps=”” rt_row_shadows=”” rt_row_borders=”” rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”cover” rt_bg_position=”right top” rt_bg_attachment=”scroll” rt_bg_layer=”” rt_bg_video_format=”self-hosted” rt_class=”rt-1561408″ rt_paddings=”10px,10px,,” rt_margins=”,,,” rt_content_margins=”,,,” rt_tablet_paddings=”,,,” rt_tablet_margins=”,,,” rt_tablet_content_margins=”,,,” rt_sp_paddings=”,,,” rt_sp_margins=”,,,” rt_sp_content_margins=”,,,”][vc_column rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”auto auto” rt_bg_position=”right top” rt_bg_attachment=”scroll”][vc_custom_heading text=”APT 3500 Smart Pressure Transmitter” font_container=”tag:h1|font_size:28|text_align:left” use_theme_fonts=”yes” css=”.vc_custom_1545890389096{margin-top: 0px !important;margin-bottom: 0px !important;padding-top: 0px !important;padding-bottom: 0px !important;}”][/vc_column][/vc_row][vc_row rt_row_background_width=”fullwidth” rt_row_content_width=”default” rt_row_style=”default-style” rt_row_height=”” rt_column_gaps=”” rt_row_shadows=”” rt_row_borders=”” rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”cover” rt_bg_position=”right top” rt_bg_attachment=”scroll” rt_bg_layer=”” rt_bg_video_format=”self-hosted”][vc_column width=”1/3″ rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”auto auto” rt_bg_position=”right top” rt_bg_attachment=”scroll”][vc_single_image image=”1704″ img_size=”full” alignment=”center” style=”zoooom” onclick=”link_image”][/vc_column][vc_column width=”2/3″ rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”auto auto” rt_bg_position=”right top” rt_bg_attachment=”scroll”][vc_column_text css=”.vc_custom_1545890403940{margin-bottom: 0px !important;}”]The APT 3500 Smart Pressure Transmitter is a microprocessor-based high-performance transmitter, which has flexible pressure calibration and output, automatic compensation of ambient temperature and process variable, a configuration of various parameters, communication with HART protocol. The application is very various, as measuring liquid, gas or steam flow as well as pressure and liquid level by an application method. All data of the sensor is to be input, modified and stored in EEPROM.[/vc_column_text][vc_custom_heading text=”Function” font_container=”tag:h2|font_size:20|text_align:left” use_theme_fonts=”yes” css=”.vc_custom_1542278081976{margin-top: 0px !important;margin-bottom: 0px !important;padding-top: 15px !important;padding-bottom: 10px !important;}”][vc_column_text]

  • Type: Pressure: Differential(DPIT), Gauge/ Absolute(PIT), Level(LIT), High Static Pressure, Flow Pressure(FIT)
  • Certificate: SIL2 (TUV, FMEDA), Ex d, Ex ia, FM, ATEX, TR CU(EAC), INMETRO, CE, Rohs, BV, LR, KR, DNV, ABS, KCs, IP66/67, NEMA 4X
  • Feature: 4 to 20mA, HART, Loop Powered
  • Accuracy: ± 0.04% of CS* 3 lines LCD display, Self Diagnostic Function, External Buttons, DAC, Zero Trim, Eng mode, Gold Plate
  • Application: Advanced performance. Pressure, Flow, Level measurement for Oil & Gas, Liquid, Water, Marine & offshore, Vessel, Power, Chemical Plants, and Refinery

[/vc_column_text][/vc_column][/vc_row][vc_row rt_row_background_width=”fullwidth” rt_row_content_width=”default” rt_row_style=”default-style” rt_row_height=”” rt_column_gaps=”” rt_row_shadows=”” rt_row_borders=”” rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”cover” rt_bg_position=”right top” rt_bg_attachment=”scroll” rt_bg_layer=”” rt_bg_video_format=”self-hosted”][vc_column rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”auto auto” rt_bg_position=”right top” rt_bg_attachment=”scroll”][vc_tta_tabs][vc_tta_section i_icon_fontawesome=”fa fa-pencil-square-o” add_icon=”true” title=”Features” tab_id=”1541150791848-f5e45dd6-3763e5d5-66a3″][vc_row_inner rt_row_background_width=”fullwidth” rt_row_content_width=”default” rt_row_style=”global-style” rt_row_height=”” rt_column_gaps=”” rt_row_borders=”” rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”cover” rt_bg_position=”right top” rt_bg_attachment=”scroll” rt_bg_layer=”” rt_bg_video_format=”self-hosted”][vc_column_inner width=”1/2″ rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”auto auto” rt_bg_position=”right top” rt_bg_attachment=”scroll”][vc_column_text]

  • High Reference Accuracy : ±0.04% of Calibrated Span
  • for range 1(DP & GP)
    ±0.10% of Span
    For spans less than 4:1,
    accuracy = ± [0.025 x (URL/span)] % of span
  • for range 2 (DP & GP)
    ±0.10% of Span
    For spans less than 10:1,
    accuracy = ± [0.05 + 0.005 x (URL/span)] %

[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/2″ rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”auto auto” rt_bg_position=”right top” rt_bg_attachment=”scroll”][vc_column_text]

  • Data Configuration with HART Configurator
  • Zero Point Adjustment
  • Continuous Self-Diagnostic Function
  • Automatic Ambient Temperature Compensation
  • Fail-mode Process Function
  • EEPROM Write Protection
  • CE EMC Conformity Standards

[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_tta_section][vc_tta_section i_icon_fontawesome=”fa fa-book” add_icon=”true” title=”Specifications” tab_id=”1541150791868-27c83745-4a4ce5d5-66a3″][vc_column_text]Model Name: APT3500
Protocol: Digital Communication, HART 7, Fieldbus Foundation
Trim ability: Zero, DAC, FULL
Power supply & Load Requirement: 250 to 550 ohm @ 24 Vdc, Loop Powered
Failure Mode: Low ≤ 3.78 mA, High ≥ 21.1 mA
External Buttons: Zero & Span 2 buttons for device configuration
Process Temp. limit: -40 to 120℃ ( -104 to 248℉ )
Range Ability: 100:1
Stability: 0.125% URL for 60 months[/vc_column_text][/vc_tta_section][vc_tta_section i_icon_fontawesome=”fa fa-file-text” add_icon=”true” title=”Documents” tab_id=”1541151331745-25407355-c006e5d5-66a3″][vc_column_text]  Catalog

 Manual[/vc_column_text][/vc_tta_section][vc_tta_section i_icon_fontawesome=”fa fa-wpforms” add_icon=”true” title=”Certificates” tab_id=”1542622727840-77d404ad-c3e4″][vc_row_inner rt_row_background_width=”fullwidth” rt_row_content_width=”default” rt_row_style=”global-style” rt_row_height=”” rt_column_gaps=”” rt_row_borders=”” rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”cover” rt_bg_position=”right top” rt_bg_attachment=”scroll” rt_bg_layer=”” rt_bg_video_format=”self-hosted”][vc_column_inner width=”1/2″ rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”auto auto” rt_bg_position=”right top” rt_bg_attachment=”scroll”][vc_column_text]  NEP

 ATEX Ex d

 IEC Ex ia

 EAC (TR CU) Ex d & Ex ia[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/2″ rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”auto auto” rt_bg_position=”right top” rt_bg_attachment=”scroll”][vc_column_text]  KCs Ex d

 ATEX Ex ia

 SIL2[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_tta_section][vc_tta_section i_icon_fontawesome=”fa fa-files-o” add_icon=”true” title=”Drawings” tab_id=”1542622803439-2655446a-e602″][vc_row_inner rt_row_background_width=”fullwidth” rt_row_content_width=”default” rt_row_style=”global-style” rt_row_height=”” rt_column_gaps=”” rt_row_borders=”” rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”cover” rt_bg_position=”right top” rt_bg_attachment=”scroll” rt_bg_layer=”” rt_bg_video_format=”self-hosted”][vc_column_inner width=”1/2″ rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”auto auto” rt_bg_position=”right top” rt_bg_attachment=”scroll”][vc_column_text]  3500-D OUTLINE

 3500-HS OUTLINE[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/2″ rt_bg_effect=”classic” rt_bg_image_repeat=”repeat” rt_bg_size=”auto auto” rt_bg_position=”right top” rt_bg_attachment=”scroll”][vc_column_text]  3500-G OUTLINE